A .strings value may span several physical lines, so deleting such an
entry line by line leaves orphaned lines that the parser folds into the
preceding value. Every key behind that point then disappears at runtime
while plutil -lint still reports OK. Tab titles are looked up without a
defaultValue:, so the tab bar rendered raw keys like "tab.overview"
while the rest of the UI fell back to its English defaults.
LocalizationIntegrityTests parses each table out of the app bundle and
fails on multi-line values, on missing keys that have no fallback, and
on leftover cable.pro.* entries. LocalizedTabBarUITests launches the app
in German and asserts the tab bar is translated.
recommendedCrossSection now satisfies two criteria and takes whichever
demands more copper: the voltage-drop budget, and an ampacity at least
as high as the fuse protecting the circuit (ABYC E-11: the OCP rating
must not exceed the conductor's ampacity). Ampacity comes from ABYC
E-11 Table 6A for AWG and ISO 13297 Table A1 for mm², both 105 °C.
Before this, a 40 A load over 0.5 m was sized 1.5 mm² / AWG 16 next to
a 50 A fuse: a cable the fuse can never protect. Long runs stay
voltage-drop driven and unchanged.
The drop budget is now stored per system (3 / 5 / 10 %) and editable in
the system editor, with a global default in Settings that the
standalone calculator uses and new systems inherit.
Cross-sections are derived, never entered by the user, so LoadCableSync
re-derives them when a system opens and when its budget changes.
Library loads are computed instead of being stored as a 1.0 mm²
placeholder. LoadConfigurationStatus therefore reports only what the
user can actually fix: missing length or current.
Also removes the dead cable.pro.* strings and folds three copies of the
mm²-to-AWG conversion into ElectricalCalculations.nearestAWG.
ComponentLibraryItem gained componentCategory, which left the test
target uncompilable. Add the argument to all call sites and a
regression test for displayVoltage skipping a zero voltageIn.
Replace client-side Amazon affiliate resolution with server-side
redirects via voltplan.app/{componentId} and voltplan.app/search?q=.
Remove AmazonAffiliate, affiliate link fetching, and per-model
affiliate fields in favor of a single componentID.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Fix AWG 0/00/000/0000 bug (all resolved to 0 in Swift) using negative
int convention (-1 through -4) with formatAWG() for 1/0–4/0 display
- Add 7.5A fuse size and change fuse type from Int to Double
- Add alternator power source type with distinct bolt.car.fill icon
- Migrate all NSLocalizedString calls to String(localized:defaultValue:)
- Update translations for runtime subtitle (ES/FR/NL: current→maximum),
usable capacity footer text, and NL override wording
- Store length always in meters, convert at display time in CalculatorView
- Add preview-friendly inits for ComponentLibraryView and LoadsView
- Expand test coverage for calculations, fuses, AWG, and edge cases
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
- Add dutyCyclePercent and defaultUtilizationFactorPercent to ComponentLibraryItem
with normalization logic and backend field fetching
- Change default dailyUsageHours from 1h to 24h
- Replace goal editor stepper with day/hour/minute wheel pickers
- Update app icon colors and remove duplicate icon assets
- Move SavedBattery.swift into Batteries/ directory, remove Pods group
- Add iPad-only flag and start frame support to screenshot framing scripts
- Rework localized App Store screenshot titles across all languages
- Add runtime goals and BOM completed items to sample data
- Bump version to 1.5.1 (build 41)